BRHMT - PYROMET X750 HI TEMP ALLOY EQUALIZED

  • MSDS: BRHMT
  • Manufacturer: CARPENTER TECHNOLOGY CORP
  • Product Name: PYROMET X750 HI TEMP ALLOY EQUALIZED
  • National Stock Number: 9510-00N038813
Product Identification

Product ID:PYROMET X750 HI TEMP ALLOY EQUALIZED
MSDS Date:05/08/1989
FSC:9510
NIIN:00N038813
MSDS Number: BRHMT

Responsible Party
CARPENTER TECHNOLOGY CORP
READING, PA 19612-4662
US

Emergency Phone: 215-371-2000

Info Phone: 215-371-2000

Cage: 71321

Contractor
CARPENTER TECHNOLOGY CORP
14662 READING, PA 19612-4662 US

Telephone: 610-208-2134 / 610-208-2457/2457

Cage: 71321

Ingredients

ALLERGIC SKIN RASH. NICKEL & ITS CMPNDS HAVE BEEN

RTECS: 9999999ZZ


CONSIDERED TO BE A "NUISANCE" PARTICULATE.

RTECS: 9999999ZZ


CONCENTRATIONS. SLIGHT LUNG CHANGES MAY OCCUR.

RTECS: 9999999ZZ


NICKEL (SARA III)

CAS: 7440-02-0

RTECS: QR5950000

Fraction By Weight: 38.5%

OSHA PEL 1 MG/M3

ACGIH TLV: 0.05 MG/M3


CHROMIUM (SARA III)

CAS: 7440-47-3

RTECS: GB4200000

Fraction By Weight: 15.5%

OSHA PEL 1 MG/M3

ACGIH TLV: 0.5 MG/M3

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


IRON (III) OXIDE

CAS: 1309-37-1

RTECS: NO7400000

Fraction By Weight: 7%

OSHA PEL 10 MG/M3 (FE)

ACGIH TLV: 5 MG/M3(FE),B2; 9293


TITANIUM OXIDE; (TITANIUM)

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 2.5%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


ALUMINUM (SARA III)

CAS: 7429-90-5

RTECS: BD0330000

Fraction By Weight: 0.80%

OSHA PEL 15MG/M3 DUST;5 FUME

ACGIH TLV: 10MG/M3 DUST;5 FUME


COBALT (SARA III)

CAS: 7440-48-4

RTECS: GF8750000

Fraction By Weight: 35%

OSHA PEL 0.1 MG/M3;AS CO

ACGIH TLV: 0.05 MG/M3;DUST 9293


COPPER (SARA III)

CAS: 7440-50-8

RTECS: GL5325000

Fraction By Weight: 0.50%

OSHA PEL 1MG/M3 DUST;0.1 FUME

ACGIH TLV: 1MG/M3 DUST;0.2 FUME

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


MANGANESE (SARA III)

CAS: 7439-96-5

RTECS: OO9275000

Fraction By Weight: 0.2%

OSHA PEL (C) 5 MG/M3 DUST

ACGIH TLV: 5 MG/M3 DUST 9293


X-RAY CHANGES OF THE LUNGS, BUT DOES NOT CAUSE

RTECS: 9999999ZZ


MANGANESE FUME MAY CAUSE "METAL FUME FEVER" W/SYMPS

RTECS: 9999999ZZ


MUSCLE ACHES, & A SWEET OR METALLIC TASTE IN MOUTH.

RTECS: 9999999ZZ


SYS, W/DIFFICULTY IN WALKING & BALANCING,

RTECS: 9999999ZZ


W/MEMORY OR JUDGMENT, UNSTABLE EMOTIONS OR UNUSUAL

RTECS: 9999999ZZ


BY A PNEUMONIA LIKE ILLNESS W/SYMPS OF COUGHING,

RTECS: 9999999ZZ


FUMES ARE RESP IRRIT &

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ALUMINUM: METAL DUSTS & OXIDE IS
GENERALLY CONSIDERED A "NUISANCE" PARTICULATE. MAY CAUSE IRRIT OF
THE EYES, NOSE, & THROAT IN EXCESSIVE CONCENTRATIONS. CHROMIUM:
FERROCHROME ALLOYS HAVE BEEN ASSOCIAT ED W/LUNG CHANGES IN WORKERS
EXPOSED TOTHESE ALLOYS. COBALT: FUME/DUST CAUSES IRRIT OF THE NOSE
& (EFTS OF OVEREXP)
Explanation of Carcinogenicity:COBALT:GRP 2B
(IARC)52,363,91-NICKEL:ANTICIPATED TO BE A CARCIN (NTP)6'TH ANN
RPT,'91, GRP 2B (IARC)49,257,90.
Effects of Overexposure:HLTH HAZ:THROAT & MAY CAUSE AN ALLERGIC SKIN
RASH. ALSO HAS BEEN REPORTED TO CAUSE RESPIRTORY DISEASE WITH SYMPS
RANGING FROM COUGH & SHORTNESS OF BREATH TO PERMANENT DISABILITY &
DEATH. THE SYMPS FRE QUENTLY GO AWAY WHEN EXPOSURE HAS STOPPED, BUT
SOMETIMES THE SYMPTOMS PROGRESS AFTER EXPOSURE HAS CEASED. (SUPP
DATA)
Medical Cond Aggravated by Exposure:MED CNDTNS, THAT ARE RECOGNIZED AS
BEING POSSIBLY SUSCEPTABLE TO AGGRAVATION BY EXPOS INCL:
PRE-EXISTING CHRONIC SKIN, EYE/RESP DISORDERS IF PRLNGD/RPTD
OVEREXP TO FUME & DUST OCCUR.

First Aid

First Aid:INHAL: MOVE PERSON TO FRESH AIR UNTIL RECOVERED, CONSULT A
PHYSICIAN. SKIN: WASH WITH WATER AND MILD DETERGENT, CONSULT A
PHYSICIAN. EYE: FLUSH THOROUGHLY WITH WATER FOR AT LEAST 15 MIN,
CONSULT A PHY SICIAN. INGEST: WHILE INGESTION OF LARGE ENOUGH
QUANTITIES TO CAUSE HEALTH EFFECTS IS UNLIKELY, CONSULT A PHYSICIAN
IF IT OCCURS.

Fire Fighting

Extinguishing Media:EXTINGUISHING MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:UNLESS OTHERWISE NOTED, NONE. PRODUCT IS
SOLID METAL.

Accidental Release

Spill Release Procedures:PRODUCT IS A SOLID METAL AS SHIPPED. NO
POTENTIAL FOR SPILL OR LEAK.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:IF YOUR PROCESS CAUSES A RELEASE OF DUST OR FUME
IN EXCESS OF THE PERMISSIBLE EXPOSURE LIMIT, NIOSH/MSHA APPROVED
RESP FOR PROTECTION AGAINST AIRBORNE DUST OR FUMES SHOULD BE WORN.
RESP SHOULD BE USED I/A/W 29CFR1910.134.
Ventilation:IF YOUR PROCESS CAUSES A RELEASE OF DUST/FUME, USE LOC &
GEN EXHST VENT TO KEEP AIRBORNE CONC OF DUST/FUMES BELOW TLV.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:BARRIER CREAMS MAY BE NECESSARY TO PREVENT
SKIN SENSIT & DERM.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: COPPER: FUME/DUST CAUSES IRRIT OF EYES, NOSE, THROAT &
A FLU-LIKE ILLNESS CALLED METAL FUME FEVER. SYMPTOMS INCLUDE FEVER,
MUSCLE ACHES, NAUSEA, CHILLS, DRY THROAT, COUGH, WEAKNESS, A ND
SWEET OR METALLIC TASTE IN MOUTH. IRON OXIDE: RPTD EXPOS TO IRON
OXIDE OVER A PERIOD OF YEARS MAY CAUSE (ING 9)

Chemical Properties

Boiling Pt:B.P. Text:HIGH
Melt/Freeze Pt:M.P/F.P Text:>2400F,>131
Vapor Pres:NIL
Vapor Density:NIL
Spec Gravity:7.5-8.5
Solubility in Water:INSOLUBLE
Appearance and Odor:SOLID, ODORLESS METAL.

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,
STATE AND LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.